Fire pump sets
Main electric, diesel and jockey pumps with controllers and header piping.
Fire Detection, Suppression & Protection
Fire protection engineered to the hazard, approved for the building.
Yonah Engineering specializes in the complete design, supply, installation, testing and commissioning of fire protection systems for commercial and industrial buildings. Our systems comply with NFPA, local fire-safety regulations and national and international fire codes.




Talk to our engineers for a free consultation, site survey and competitive quote.
Where We Work
Fire Protection Systems we design and install for every kind of facility.
Systems & Equipment
Main electric, diesel and jockey pumps with controllers and header piping.
Sprinkler networks, hydrant valves, hose reels and fire brigade inlets.
Clean-agent and CO₂ systems for server rooms, panels and archives.
Detectors, call points, panels and voice evacuation speakers.
Our Process
How we deliver safe, reliable Fire Protection Systems on every project.
Hazard class, occupancy, water source and site conditions.
Hydraulic calculations, detection layouts and system drawings.
Drawings and documents for the fire department NOC.
Pumps, valves, piping, detectors and suppression equipment.
Installation, flow and pressure tests, and NOC inspection.
Standards & Codes
The design references our engineers work to on every project.
Recent Work
Fire ProtectionComplete fire pump room with main, standby and jockey pumps, suction and delivery headers and pump controllers.
Fire ProtectionLarge-bore fire protection headers and risers routed through the pump room and service corridor.
Fire ProtectionFire pump sets with suction strainers, isolation valves and delivery piping on raised plinths.
FAQs
Answers to what clients most often ask us about Fire Protection Systems.
Wet, dry and pre-action sprinkler systems, fire hydrant and hose reel systems, gas detection and suppression, fire alarm and PA systems, and portable fire extinguishers — designed together so they work as one system.
Yes. We handle design, engineering and execution, and prepare the layout drawings, hydraulic calculations and test records needed for the fire department NOC, then support you through the inspection.
In rooms where water would damage equipment or records, such as server rooms, electrical panel rooms and archives. A clean-agent or CO₂ system detects the fire and floods the room with gas instead of water.
Yes. We survey the installation, check its capacity against the current hazard and occupancy, then retrofit pumps, piping, detection or suppression as needed.